Gate End Boxes & Starters

Control Panels, Gate End Boxes and Starters

Dual Drive Starters, Reversing Contactor Starters, Star Delta Starters, Remote Operation, Master/Slave Operation Starters, Cascading Starters, Gate End Boxes, Direct On Line Motor Control Panel/Starters, TYPE CP 1,CP-2 & 3, CP5

CP 5 CHASSIS FRONT VIEW
  • These are available in voltages ranging upto 650 volts in the low voltage range.
  • These are available for operation of motors, in capacities ranging from fractional kW rating to 300 kW.
  • Choice of motor protections ranging from magnetic/thermal overload relays/ thermister control relays, single phasing protection, and surge suppressors, soft starts.
  • CP 5 DOOR OPENChoice of earth leakage relays ranging from sensitive earth leakage protection from 80mA to 2-5 amps leakage relays with preset or choice of time delays.
  • Choice of oil dashpot type magnetic overload relay with time lags or thermal overload relays available.
  • Short circuit protection through solid-state relays or fuses as desired.
  • Single phasing prevention may be provided if desired.
  • Choice of contactors to suit clients requirements with double air break block type of vacuum contactors.
  • Choice of remote/local control available.
  • Mechanically and electrically interlocked Isolators fitted in separate flameproof enclosure.
  • Metering through voltmeter, ammeter, kilo-ohm meters available.
  • CP 5 SHOWING FIXED CONTACTS MOUNTED ON ENCLOSUREIntertrunking possible with the use of busbars upto 300 amps in capacity.
  • Choice of pull cord, beltsway, zero speed, overspeed,and other interlocks for conveyor control available.
  • Master, slave or dual drive or reversing control versions of this starter is available.
  • Incoming, outgoing, throughgoing provided by means of cable sealing boxes, terminal boxes and blanking covers as and where necessary.
  • Insulation monitoring devices may be supplied for insulated neutral systems with search and lockout relays.
  • Remote/local operation possible.

FLAMEPROOF DIRECT ON LINE STARTERS, TYPE CP 5 .

  • Extremely light and compact starter ideally designed for mobility when it is needed to drive small pumpsets and auxiliary fans at face.
  • Available with airbreak contactors upto 50 amps AC3 ratings.
  • Mechanically and electrically interlocked Isolator fitted in separate flameproof chamber.
  • Selection of earth leakage relay, with adjustable leakage setting between 2-5 amps, Visual indications of earth trip, with test and reset mechanism.
  • Choice of single phasing preventor may be provided.
  • Short circuit protection through HRC fuses.
  • Busbars upto 300 amps
  • Ammeters
  • Remote/local selection
  • All components mounted on fully withdrawable chassis fitted with butt contacts on reverse. No need to disconnect cables whilst withdrawal of chassis.

CP 5 WITH MAIN DOOR OPEN SIDE VIEW

Gate End Box

FLAMEPROOF GATE END BOXES/STARTERS TYPE GEB-1 & 2

  • Suits operation of motors such as SDL's, LHD's, conveyors, coal cutting machines, shearers, pumps, fans where various remote control features are required.
  • Operating voltage upto 650 Volts.
  • Outgoing trailing cable connections are taken out through Plugs and Sockets of 200 capacity (see elsewhere in this catalogue.
  • Choice of air break or vacuum contactors.
  • Electrically and mechanically interlocked Isolators upto 400 amps fitted in separate enclosure with provisions for ON/OFF/EARTH, ON/OFF/REVERSE, or ON/OFF.
  • Choice of motor protection range from Magnetic/thermal/solid State overload protection, earth leakage protection, search and lockout of deteriorating insulation protection in preset ranges. For choice of relays look elsewhere in this catalogue.
  • Visual indication of earth leakage trip with test/reset feature.
  • Other motor protections that may be provided are single phasing preventors, surge suppressors,
  • For specific details on earth leakage protection see STARTERS as above, or elsewhere in this catalogue.
  • Metering available as per client's choice for voltmeters,ammeters,kilohm meters
  • Intrinsically safe connections provided to accommodate upto 18 interlocks to provide pull chord, beltsway, zero speed, and other necessary protections and sequence.
  • Incoming, throughgoing cable connections provided by means of cable sealing and terminal boxes.

gate end box front view

K4 GEB ISOLATOR

Delta 2FLAMEPROOF STAR/DELTA STARTERS TYPE CP/SD-1&2

  • Available in voltages upto 650 volts.
  • Choice of motor protections as in above descriptions for gate end boxes and starters.
  • Choice of incoming, throughgoing and outgoing cable entries as in starters above.
  • Suits operation for compressors, conveyors, fans etc, or motors requiring higher starting torque's.
  • Rest as above.

Delta 3FLAMEPROOF BOLTLESS GATE END BOXES FOR 1100 VOLTS OR 550 VOLTS OPERATION, TYPE DESIGNATION DELTA

  • AIR BREAK/VACUUM CONTACTORS UPTO 400 AMPS
  • Quick opening, gate end box with single security bolt for operation in various applications from conveyors to shearers.
  • Suitable for trunking several Gate End Boxes of different applications on a single bank formation for longwall faces.
  • Conforming to IS 2148, BS 5126, EN 50014, 50015.
  • Entire active parts mounted on sliding rails fitted with butt and stab contacts at the rear of the active chassis.
  • No need to disconnect any cables while withdrawing active chassis.
  • CP 5 SIDE VIEWFor description of various choices for earth leakage protection please turn to relevant section of the catalogue.
  • Choice of Thermal/solid State overload protection.
  • Surge suppressors available on choice.
  • A plug and socket to take out outgoing cables. (Turn to relevant section).
  • Mechanically and electrically interlocked Isolators upto 400 amps mounted in a separate flameproof chamber.
  • Throughgoing arrangement may be provided with intertrunking chambers. Possible to bank two or more gate end boxes in a single panel formation.
  • Incoming cable entries through cables terminal and sealing boxes.
  • Other protections include, single phasing prevention, short circuit protection.
  • Metering provided by voltmeter, ammeter, continuous insulation monitoring meter, and other protections.
  • Interlocks available with suitable outgoing intrinsically safe outlets to monitor belt speed pull cord or such parameters.
  • Interchangeable with imported gate end boxes.

FLAMEPROOF 3300/6600 VOLTS STARTERS TYPE DESIGNATIONS EX-630S

  • Available in either 3300 volts or 6600 volts with choice of air break or vacuum contactors in 3300 volts and only vacuum contactors in 6600 volts.
  • Mechanically and electrically interlocked Isolator mounted in a separate flameproof chamber.
  • Visual indication of disengagement of Isolator/and Earth connection contacts possible through special window for additional safety.
  • Earth leakage protections available according to choice on separate section on this catalogue.
  • Visual indication of earth trip with test and reset buttons provided on front cover.
  • Choice of other protections are available, such as overload protection, short circuit protection, single phasing protection or any other such protections specified by the client are available according to the choice of the client.
  • Incoming and outgoing cable entries are provided through cable terminal boxes, cable couplers and adopters.
  • Through going cable entries are possible through throughgoing cable entry boxes
  • Possible to bank two or more starters in single panel formation.
  • Choice of ammeters, voltmeter, insulation monitoring meter etc. are available according to choice of client.
  • Single or dual drive versions available
  • Specially designed 15 KVA, 3.3/550/110/15V Volts, 3 phase transformers can be provided for auxiliary drives and lighting banked with this starter.. Use of this transformer elimates the need for separate cables for lighting, pump and fan loads .
CP 5 FRONT VIEW

gate end box power plate

Gate end Box Interior

<< Back to Products